SPW600 windows – is a high performance commercial window system designed to meet the latest thermal insulation demands. It includes fixed lights, tophung, sidehung, tilt-turn, and overswing windows. They are constructed with a three chamber, 75mm polyamide thermally broken aluminium and are available in single or dual colours.
If you would like more information or to place your order please give us a call on 01484 650000 or fill out the contact form.
- Weather rating tested to BS 6375 1:2009 achieving 600Pa air permeability, 600Pa water tightness and 2400Pa wind resistance.
- Thermally enhanced options earn BFRC ratings
- Extremely versatile with a wide range of sections and ironmongery for many differing projects.
- SPW600e is an enhanced version of the SPW600 with the addition of polystyrene and backer rod inserts.
- Available in two finishes:
- Polyester powder coating to BS EN 12206: 2004 Part 1 – painted in single or dual colour and surface finish at 40 microns, or enhanced to 60 microns for marine environments.
- Anodised and Anolok finishes are to BS3897: 1991 to a minimum of 25 microns (AA25), supplied in either satin or polished finish.
Casement Open Out
Typical* Sizes | |||
---|---|---|---|
Width(mm) | Height(mm) | ||
Top Hung Out | 1500 | X | 1500 |
Side Hung | 900 | X | 1500 |
Security |
---|
Tested to BS7950, Security hardware required |
Glazing | |||
---|---|---|---|
Thickness | 26mm | to | 56mm |
Average U Values – SPW600 | |||
---|---|---|---|
1200 x 1200 | 1500 x 1500 | ||
Fixed Vent | 1.45 W/m2K | 1.40W/m2K | |
Vent | 1.65 W/m2K | 1.57 W/m2K |
Weather rating (BS6375) | |
---|---|
Air Permability | 600 Pa |
Water Tightness | 600 Pa |
Wind Resistance | 2000 Pa |
The full data sheet can be found here.
Inward Opening Tilt/Turn
Typical* Sizes | |||
---|---|---|---|
Width(mm) | Height(mm) | ||
Tilt/Turn | 1500 | X | 1500 |
Tilt/Turn Heavy Duty | 1500 | X | 2200 |
Minimum Sizes | |||
Tilt/Turn | 450 | X | 500 |
Weather rating BS6375 Part 1 | |
---|---|
Air Permability | 600 Pa/Class C |
Water Tightness | 600 Pa |
Wind Resistance | 2400 Pa |
Security |
---|
Tested to BS7950, Security hardware required |
Average U Values – SPW600 | |||
---|---|---|---|
1200 x 1200 | 1500 x 1500 | ||
Fixed Vent | 1.49 W/m2K | 1.44W/m2K | |
Vent | 1.67 W/m2K | 1.59 W/m2K |
Average U Values – SPW600e | |||
---|---|---|---|
1200 x 1200 | 1500 x 1500 | ||
Fixed Vent | 1.39 W/m2K | 1.34W/m2K | |
Vent | 1.57 W/m2K | 1.49 W/m2K |
Glazing | |||
---|---|---|---|
Thickness | 26mm | to | 56mm |
The full data sheet can be found here.